    Using thermochromism to simulate blood oxygenation in extracorporeal membrane oxygenation

    Get PDF
    Introduction: Extracorporeal membrane oxygenation (ECMO) training programs employ real ECMO components, causing them to be extremely expensive while offering little realism in terms of blood oxygenation and pressure. To overcome those limitations, we are developing a standalone modular ECMO simulator that reproduces ECMO’s visual, audio and haptic cues using affordable mechanisms. We present a central component of this simulator, capable of visually reproducing blood oxygenation color change using thermochromism. Methods: Our simulated ECMO circuit consists of two physically distant modules, responsible for adding and withdrawing heat from a thermochromic fluid. This manipulation of heat creates a temperature difference between the fluid in the drainage line and the fluid in the return line of the circuit and, hence, a color difference. Results: Thermochromic ink mixed with concentrated dyes was used to create a recipe for a realistic and affordable blood-colored fluid. The implemented “ECMO circuit” reproduced blood’s oxygenation and deoxygenation color difference or lack thereof. The heat control circuit costs 300 USD to build and the thermochromic fluid costs 40 USD/L. During a ten-hour in situ demonstration, nineteen ECMO specialists rated the fidelity of the oxygenated and deoxygenated “blood” and the color contrast between them as highly realistic. Conclusions: Using low-cost yet high-fidelity simulation mechanisms, we implemented the central subsystem of our modular ECMO simulator, which creates the look and feel of an ECMO circuit without using an actual one.Peer reviewedFinal Accepted Versio

    Comparison of in-hospital and out-of-hospital cardiac arrest of trauma patients in Qatar

    Get PDF
    Background Cardiac arrests in admitted hospital patients with trauma have not been described in the literature. We defined "in-hospital cardiac arrest of a trauma" (IHCAT) patient as "cessation of circulatory activity in a trauma patient confirmed by the absence of signs of circulation or abnormal cardiac arrest rhythm inside a hospital setting, which was not cardiac re-arrest." This study aimed to compare epidemiology, clinical presentation, and outcomes between in- and out-of-hospital arrest resuscitations in trauma patients in Qatar. It was conducted as a retrospective cohort study including IHCAT and out-of-hospital trauma cardiac arrest (OHTCA) patients from January 2010 to December 2015 utilizing data from the national trauma registry, the out-of-hospital cardiac arrest registry, and the national ambulance service database. Results There were 716 traumatic cardiac arrest patients in Qatar from 2010 to 2015. A total of 410 OHTCA and 199 IHCAT patients were included for analysis. The mean annual crude incidence of IHCAT was 2.0 per 100,000 population compared to 4.0 per 100,000 population for OHTCA. The univariate comparative analysis between IHCAT and OHTCA patients showed a significant difference between ethnicities (p=0.04). With the exception of head injury, IHCAT had a significantly higher proportion of localization of injuries to anatomical regions compared to OHTCA; spinal injury (OR 3.5, 95% CI 1.5-8.3, pPeer reviewe

    Cost-efficiency assessment of Advanced Life Support (ALS) courses based on the comparison of advanced simulators with conventional manikins

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Simulation is an essential tool in modern medical education. The object of this study was to assess, in cost-effective measures, the introduction of new generation simulators in an adult life support (ALS) education program.</p> <p>Methods</p> <p>Two hundred fifty primary care physicians and nurses were admitted to ten ALS courses (25 students per course). Students were distributed at random in two groups (125 each). Group A candidates were trained and tested with standard ALS manikins and Group B ones with new generation emergency and life support integrated simulator systems.</p> <p>Results</p> <p>In group A, 98 (78%) candidates passed the course, compared with 110 (88%) in group B (p < 0.01). The total cost of conventional courses was €7689 per course and the cost of the advanced simulator courses was €29034 per course (p < 0.001). Cost per passed student was €392 in group A and €1320 in group B (p < 0.001).</p> <p>Conclusion</p> <p>Although ALS advanced simulator systems may slightly increase the rate of students who pass the course, the cost-effectiveness of ALS courses with standard manikins is clearly superior.</p
    corecore